Part # MMF0289Perfect for static surveys, the Model 289 with its Hi-Res Bar-graph display quickly reads either positive or negative values up to 10kV, or as low as 100V. Now there's no excuse for letting static buildup cause costly damage. Integrating proven measurement techniques with the latest technology you'll want one instantly available wherever static can strike. |
|
|
Model 244ALDesigned for contact potential measurements, electrophotographic measurements, electret measurements, and radiation effects on insulators and semiconductors, the Model 244AL is a quality instrument for measuring electrostatic surface potential without physical contact. The Model 260 has a range of +or- 15Volts, with a surface resolution of approximately 0.1” at a probe to surface spacing of 0.5mm. |
|
|
|
|
Model 262A is designed to produce fast, repeatable measurements of both surface resistivity and resistance to ground. Featuring automatic ranging from 10E4 to 10E14 ohms or ohms/sq., and + or - 1/2 decade accuracy, Model 262A checks resistivity specifications on static control products such as ESD shielding bags, static dissipative mats and conductive work surfaces, and checks continuity of work surfaces to ground. The fully portable, battery-operated unit provides 8 hours steady use. Conforms to ASTM-D257 standards by using recommended parallel bar sensing probe and 100V measuring voltage. |
|
|
|
Miniature Surface ProbesWe offer a new series of custom, miniature surface resistivity probes for use with our Models 264, 262A, and 272A. The units are useful in measuring irregularly shaped objects such as DIP tubes and thermoformed plastic carriers. |
Miniature Guard Ring0.47"o.d. x 6.0"L probe with 0.1"dia. inner electrode size |
Point to Point ProbeConsisting of two (2) 0.1" diameter, interchangeable pogos mounted
0.4" center to center. |
Model RT-06The Richmond Model RT-06 measures both surface resistivity and resistance to ground giving simple, repeatable measurements of conductive, static dissipative, and insulative surfaces. The meter employs the ASTM-257 method of parallel bar sensing. |
Model RT-03The Richmond Model RT-03 measures surface resistance to ground and point to point resistance using two 5# weights electrode and the new ESD S4.1 specified voltage (10V for conductive and 100V for dissipative). Its analog scale is autoranging from 10E3 to 10E12 and insulative. |
Model M3The M3 Wrist Strap Checker is an easy to use, hand held tester for all types of wrist straps and ground leads. It is a compact, portable unit that reliably indicates the condition of the wrist strap, ground lead, and interface to the user's skin. If system resistance is too high (greater than 10 megohm) or too low (less that 800kilohm) an audible alarm will sound and either the high or low indicator will light. If system resistance is within the satisfactory range, the "OK" indicator will light. |
9 V AC / DC Converter for M3 |
Model RT-01The RT-01 easily measures the resistance of a wristband and cord or heel/toe grounder (with optional footplate) worn by the operator. The RT-01 tests the range of 750 kilohms to 10 megohms with European ranges of 900 kilohms to 35 megohms available. |
|
Model TIFPThis metal footplate and interconnecting cord can be used in conjunction with Models M3, RT-01, and 275 to perform heel/toe grounder testing. |
Part # MRE0400The Tester Station is an easy to use test mechanism for personnel grounding devices. If system resistance is too high (greater than 10 megohm) or too low (less that 750kilohm) either the high or low indicator will light. An audible alarm will sound if system resistance is within the satisfactory range, and the "OK" indicator will light. System comes complete with tester, footplate, and wall mounting sign with instructions. |
Model M70DThe M70D is designed specifically to provide in-line continuous monitoring of Dual Line wrist straps, and is flexible enough to allow two operators and two stations to be monitored at the same time. Resistance is measured 100% of the time through the dual leads providing continuous verification. The Model M70D is designed to the highest standards, utilizing patented resistive loop technology for consistent operation. |
Model RT-05The RT-05 continuously monitors the presence of ground and the continuous connection of the wrist strap to the operator. The RT-05 provides a constant capacitive measurement of the operator but a resistive ( up to 2.3 megohm ) constant measurement of ground. At the first sign of a faulty connection, the red LED will flash and an audible alarm will sound. |
Part # M60aThe M60a Two Station Wrist Strap Monitor System continuously monitors
one or two ESD Work Surfaces and one or two conductive wrist straps to detect
loss of continuity. Conditions such as ungrounded work surfaces or broken
cords and improper wearing by operators are detected instantly to alert
the operator to take corrective action before serious and expensive losses
can occur due to ESD. |
|
Model 268-1TModel 268-1T offers all of the features of the standard Model 268, and adds the capability of adjusting the low end stop point for timed decay measurements from 1v to 1000v in 1v increments. |
|
|
|
DataStatThe Datastat 2000 is a portable instrument used to record and evaluate static voltage on people and equipment. It stores information in memory until downloaded to a computer where it can then be graphed analyzed throught user-friendly software. Min/max voltages, elapsed decay times and script can be added to enhance the visual display. |
Model 287IPATest any and all ionizers as simply as touching a button! The Model 287 Ionization Performance Analyzer performs manual or automatic decay and balance tests for periodic verification of ionization equipment. It then stores the results and averages decay times for up to 10 manual tests and up to 10 complete automatic test sequences. Temperature and relative humidity are displayed real time and recorded with the test data. |
|
Model 910A completely integrated system for simulating ESD events to determine the susceptibility level of electronic devices to electrostatic discharge. With both manual and automatic modes, the fully adjustable, dual polarity 10kV system meets the requirements of MIL STD 883C, Notice 8, Method 3015.7, with the capability of performing Human Body Model discharge testing up to +or- 8kV. Plug-in capacitor and resistor modules allow the user to easily alter the HBM R & C values. The Model 910 interfaces with the device under test by means of a pair of miniature test leads and the standard plug-in adapter module. Optional adapter modules are available for unique I/O pin configurations. |
|
|
Model 431The Model 431 Shielded Bag Test System is designed to perform both the EIA-541 and the ESD S11.31 tests when used in conjunction with the appropriate user supplied oscilloscope and computer. |
|
|
Model RT-07The RT-07 is a unique, battery operated static voltage meter designed specifically as a visual indicator for showing static built up on a person. One touch from a finger will trigger a LED showing between zero and 19,999 volts and its polarity. |